delivered the opinion of the court.
On December 6, 1907, near the station of Mace, in the state of Idaho, locomotive engine No. 79 belonging to the defendant railway company exploded, so injuring the engineer, William Copenhaver, that he died some days later. His fireman, Buis, was also killed. This action is prosecuted by Copenhaver’s wife and minor son to recover damages sustained by his death. A jury fixed such damages at $12,000, and judgment was entered *462accordingly. From the judgment and an order denying a new trial, defendant has appealed.
The complaint charges that “the boiler and parts thereof were in a dangerous, defective, and worn-out condition and wholly unfit for the uses to which they were put at the time of said accident.” No specific defect is mentioned. There was testimony to the effect that the crown-sheet of the engine had been burned about a week or ten days prior to the explosion while the machine was in the roundhouse at Wallace. Considerable doubt was thrown upon the truth of this testimony by other evidence in the case; but we cannot say that its probative force was entirely destroyed. That was a question for the jury to decide. There was an old patch on the flange joining the flue-sheet and the crown-sheet of the engine. It was placed on the outside of the fire-box, and plaintiffs’ witnesses declared that it should have been placed on the inside. Seven flues had been removed at the point in question, and the flue holes filled or plugged by placing “sunflowers” therein. One of the principal points in issue was whether the patch was properly put on. After the explosion a part of it remained attached to the crown-sheet, showing that it had been tom apart. Whether the patch was cracked before the explosion occurred was also a mooted question at the trial. Whether the removal of so many flues weakened the holding power of the patch and the flue-sheet was also contested. The engine leaked very badly in the fire-box for some time prior to the accident. It was conceded by both sides; that the flues leaked and had been frequently caulked; but there was testimony to the effect that this would not tend to cause an explosion. Whether the crown-sheet leaked was a mooted question. Some time after the explosion it was found that three radial bolts or stays, designed to support and strengthen the crown-sheet, were missing from the wrecked boiler. Whether they were broken off before the explosion or cut off after that event was also an issue. One of defendant’s witnesses testified that he cut them off after, the explosion, and this testimony was corroborated. There was also a sharp difference of opinion be*463tween the witnesses on the respective sides as to whether or not the defective portion of the flange should have been removed before the patch was put on, plaintiffs’ witnesses testifying that it should have been, and defendant’s maintaining that the boiler was strengthened by placing the patch over the defective part without cutting out any portion of it. Defendant’s position was well defined. Its counsel maintained and claim to have proven that the explosion started in that portion of the crown-sheet at. least twelve inches distant from the flange, where the sheet had been burned just prior to the explosion, by Copenhaver allowing the water to get so low that it failed to cover the crown-sheet, which consequently became red hot, stretched, sagged, pressed downward away from the crown bolts, causing a cupped appearance between the bolt holes, and finally gave way. It was claimed that the tear or hole extended to the patch on the flange, thus causing that piece of metal to be torn apart. Defendant claimed that the appearance of the crown-sheet indicated a burning just prior to the explosion; but this was contradicted by plaintiffs’ witnesses. On the part of plaintiffs it was claimed, in effect, that on account of the defective conditions existing in the flue-sheet and crown-sheet, including the flange by which they were joined and the patch thereon, caused by negligent repairing and negligent failure to keep in a reasonably safe condition generally, the parts became so weak that they could not sustain the pressure of steam which the engine was designed to carry, and the explosion resulted. One of plaintiffs’ witnesses testified: “The defects of the boiler was the general cause of the explosion. There were three defects that would cause the explosion itself. These are: The crack in the flange, these loose radial stays, and those broken stay bolts.” Consideration of broken stay bolts was afterward withdrawn from the jury. Another witness said: “I think the boiler gave way at the patch where those two fire cracks were in the vicinity of the broken radial bolts. The explosion was due to the bad condition of the patch and the broken radial bolts. I think the crown-sheet was covered with water at the time of the explosion. Taking out *464seven flues weakens the boiler. You should put in a new. flue-sheet.” Another said: “I rode with Copenhaver on the engine from Wallace to Mace. I noticed the water in the water-glass from time to time, and that it ran from two-thirds full to full and that it moved up and down. As I got off the engine at Mace where I could see the water-glass, it was two-thirds full, and the water vibrated; that is, it moved up and down, and when you see water in the glass it is all right. It was eight or ten minutes from the time I got off until the explosion occurred. I saw Copenhaver using the injector on the way to Mace a number of times.” Several of the defendant’s expert witnesses testified that low water on the front end of the crown-sheet caused the explosion. They also said that the removal of seven flues would not weaken the boiler. There was also testimony to the effect that the top flues “showed that they had been overheated and wilted down from low water.” The actual distance from Mace station to the place of the explosion was shown to be 2,247 feet.
1. Plaintiffs’ witness Sehelega, an expert boiler-maker, familiar with boiler construction and repairs, made this statement: “The defective portion should be cut out so that the water could get to the patch, and, for another reason, that the crack could not extend any farther. This patch was not put on in the usual and customary method of patching these kinds of defects.” He was then allowed to answer this question, over objection: “State whether or not, in your opinion, it is a reasonably safe way in which to make this repair.” He answered: “It was unsafe.” This question was also objected to: “Mr. Sehelega, taking into consideration these various conditions of this engine boiler, as described by you to have existed before this explosion, and basing your opinion upon those conditions that yon have testified to as existing, you may state whether, in your opinion, that boiler was.in a reasonably safe condition for use on December 6, 1907.” The answer was: “The boiler was in an unsafe condition.” A third question was asked: “Basing your opinion upon your examination of this boiler and the vari*465ous parts, and what you discovered, state what, in your opinion,' was the cause of this explosion.” Substantially the same objection was interposed and overruled, and the witness answered: “The engine must have been burned some time before the explosion; by the contraction of the crown-sheet, the crown-bolts got loosened. The boiler-maker in charge, instead of going to work to inspect it and see if those bolts would stand another hammering, which would be done the proper way by having another man holding on the other end of the bolts, and split that thread on the inside of the crown-sheet.” Defendant’s counsel moved to strike out that portion of the answer relating to what the boiler-maker should have done as not responsive to the question. The motion was overruled. We think the ruling was technically erroneous; but, in view of the exhaustive inquiry prosecuted by both sides as to the proper manner of doing the necessary work on this boiler and fire-box, we find no prejudice in the ruling.
Recurring to the question of the competency of the interrogatories propounded to the witness: It must be borne in mind that these questions were asked before there was any conflict in the evidence and in an endeavor by the plaintiffs to make a prima facie case. Section 7887, Revised Codes, provides that a witness may give his opinion of a question of science, art or trade, when he is skilled therein. This means that an expert witness may give his opinion upon, or about, a question of science, art or trade. (Cummings v. Reins Copper Co., 40 Mont. 599, 107 Pac. 904.) In the case just cited this court said: “The general rule, however, is that [a witness] may state facts only whenever the question to be determined is the result of the common experience of all men of ordinary education, or is to be inferred from particular facts; the inference is to be drawn by the jury and not by the witness. ’ ’ In that case and in the case of Metz v. City of Butte, 27 Mont. 506, 71 Pac. 761, also cited by appellant, the court did not hesitate to say, in effect, that the jurors were as well qualified to draw the proper inference, from their own experience, as was the witness.
*466The court of appeals, in Dougherty v. Milliken, 163 N. Y. 527, 79 Am. St. Rep. 608, 57 N. E, 757, thus stated the general rule in a manner which appeals to us as being correct: “It may be broadly stated as a general proposition that there are two classes of cases in which expert testimony is admissible. To the one class belong those cases in which the conclusions to be drawn by the jury depend upon the existence of facts which are not common knowledge and which are peculiarly within the knowledge of men whose experience or study enables them to speak with authority upon the subject. If, in such cases, the jury with all the facts before them can form a conclusion thereon, it is their sole province to do so. In the other class we find those eases in which the conclusions to be drawn from the facts stated, as well as knowledge of the facts themselves, depend upon professional or Scientific knowledge or skill not within the range of ordinary training or intelligence. In such cases not only the facts, but the conclusions to which they lead, may be testified to by qualified experts. The distinction between these two kinds of testimony is apparent. In the one instance the facts are to be stated by the experts and the conclusion is to be drawn by the jury; in the other the, expert states the facts and gives his conclusion in the form of an opinion which may be accepted or rejected by the jury. The next step in the logical development of this inquiry is to ascertain to which of these two classes the case at bar belongs. If the knowledge of the experts consists in descriptive facts which can be intelligently communicated to others not familiar with the subject, the case belongs to the first class. If the subject is one as to which expert skill or knowledge can be communicated to others not versed in the particular science or art only in the form of reasons, arguments, or opinions, then it belongs to the second class.” In our judgment this case belongs to the second class. We are not able to say that an inexperienced juror could tell, after the expert witness had narrated the fact conditions as they appeared to him, whether the engine was still in a reasonably safe condition for use. Tie might know all of the fact conditions and not be able to draw a *467conclusion from them. In such case an expert could, and we have no doubt the experts in this ease did, materially enlighten the jurors upon the ultimate question to be determined. While, technically, these witnesses did not answer that question, to-wit, Was the defendant negligent? still there would be no objection had they by inference done so. The jury could either accept or reject their opinions. (Chandler v. Tompson (C. C.), 30 Fed. 38; Hutchinson Cooperage Co. v. Snider, 107 Fed. 633, 46 C. C. A. 517; Transportation Co. v. Hope, 95 U. S. 297, 24 L. Ed. 477.)
The trial court is the first judge of the competency of a witness to testify as an expert. (Yergy v. Helena L. & Ry. Co., 39 Mont. 213, 102 Pac. 310.) And when the court is unable to say, as a matter of law, that the jurors are as competent to pass upon the safety of an appliance as are men who have special knowledge on the subject, gained from experience, the evidence of such men may be admitted. (Coleman v. Perry, 28 Mont. 1, 72 Pac. 42.)
This brings us to a phase of the ease which affords a proper opportunity for a few observations concerning the duty of this court in the determination of appeals in civil actions. Section 6593, Revised Codes, provides that no judgment shall be reversed by reason of any error in the proceedings which does not affect the substantial rights of the parties. We doubt if the hench and bar of the state have given this statute the consideration, scope, force and effect to which it is entitled. It is plain and requires no interpretation. This court is commanded to give judgment on appeal without regard to errors which do not affect the substantial rights of the parties. The statute was designed to prevent reversals of causes wherein substantial justice has already been done. It was intended to put a speedy end to litigation, when that object can be attained without injustice. The power to determine the ultimate question whether the substantial rights of an appellant have been violated must reside somewhere. The Constitution framers and the legislative assembly, reaching out, apparently, toward that *468most desirable end— a fair, impartial and speedy investigation and determination of matters in issue between litigants—have vested the power in this court. Not without safeguards, however. Before a case reaches here, the appellant’s cause, in actions at law, has been adversely determined by a trial judge and a jury, unless he has waived the latter, and in all suits in equity by a chancellor; all sworn to decide according to the law and the evidence. The courts all agree that, presumptively, the initial decision is correct. That decision is simply affirmed by this court. The statute last cited will be invoked and applied in both letter and spirit, whenever in future, it is possible to do so.
Let us assume that the exceptions we have been considering were well taken, and apply the statute to this ease. Plaintiffs’ witnesses, as experts, gave opinion as to the condition of the engine boiler before the accident, and the nature and cause of the explosion. Defendant’s witnesses, also experts, arrived at conclusions altogether different. Every opportunity was viven and taken for a thorough investigation. No competent Testimony was excluded. The fact that the defendant, after the court’s ruling, was obliged to rebut the testimony of plaintiffs’ experts, is not in our judgment sufficient to take the case out of the operation of the statute. The jury was free to adopt the opinions of either set of witnesses. After inspection of the wrecked boiler, they adopted those of the plaintiffs’ experts. We think, on this branch of the ease, both parties had a fair •md impartial trial, regardless of the rulings we have just considered.
2. At the close of plaintiffs’ case the defendant moved to strike from the record ^all of the testimony relating to the alleged defects in the boiler except that relating to the patch and the cracks, and especially the testimony relating to the defective stay bolts, for the reason that it in no manner relates to the explosion as a producing cause. ’ ’ The court, by consent, granted the motion as to the stay bolts and overruled it in other respects. Appellant cannot complain of this ruling. The mo*469tion was not sufficiently specific to include evidence as to any part of the boiler, save that relating to the stay bolts.
3. Defendant offered to prove by a witness that while there exists a popular impression that metal having holes in it, when heated, will expand toward the holes and make them smaller, such impression is erroneous. The offer was refused. The popular impression was immaterial. It was defendant’s privilege to give the facts in evidence, and, as we read the record, it finally succeeded in doing so.
4. Defendant offered this instruction: “(9) Among the alleged weaknesses claimed by plaintiff is the condition of the hammer heads. It is insisted that they were worn off and weakened so as to have lost or impaired their holding power. Here the burden of proof is upon the plaintiff to show the condition of the hammer heads to have existed as she claims, and that this created such a weakness as that it did, and in the natural course of events would have been likely to have caused the explosion, and that it was a weakness without which the explosion could not have happened, and that this condition had existed so long that the defendant in the exercise of reasonable care should have discovered and repaired it.” The court struck out. “and that it was a weakness without which the explosion could not have happened,” and inserted in lieu thereof, “and that it was a weakness that contributed to the cause of the explosion.” There was no error in this action of the court. The complaint, as aforesaid, charges that the boiler and parts thereof were worn out and defective. There was no attempt to have this allegation made more specific. Schelega testified: “The defects of the boiler was the general'cause of the explosion.” Cummings said: “That fire-box, from my examination, was unfit, and had been for some time previous.” Four of plaintiffs’ witnesses testified that the engine was not in a reasonably safe condition • for use and operation, on account of the several defects in the boiler which they described. They were of opinion, as we understand, that each of the alleged defects contributed, more or less, to this weakened and unsafe condition. Defendant asked *470the court to instruct the jury that they could not consider any defect unless they were satisfied that, in its absence, the explosion could not have happened. This was not the proper rule to apply under the circumstances. It ignores the cumulative effect of the different defects. The court properly told the jury that they must disregard any defect which did not contribute to the explosion. Any defect which contributed to the general result was a proximate cause, although, had it alone existed, the boiler would have retained sufficient strength to withstand the steam pressure and would not Have exploded.
5. Defendant requested the court to charge the jury that, “if a strike existed which made it more difficult than it otherwise would have been to accomplish inspection, only such degree of vigilance would be required during the continuance of the strike as would represent reasonable care under the circumstances then existing.” The court refused the instruction. This was a correct ruling. There is some desultory testimony in the record to the effect that there was a strike among the boilermakers, but not anything appears to have been predicated upon the fact, either in the pleadings or upon the trial, prior to the tender of this instruction. The testimony is too unsubstantial to be entitled to any consideration. And, indeed, it does not appear that there was any failure to inspect or repair on account of the strike.
6. It is contended that the evidence is not sufficient to support the verdict. The testimony is in sharp conflict, and that for the plaintiffs was amply sufficient, if the jury believed it, to support ,a finding in their favor. Counsel assert that the verdict is in conflict with the undisputed physical facts disclosed, and they make a very elaborate and ingenious argument in support of their position, but we cannot agree that the question so ably presented to this court was not for the jury to decide.
The judgment and order are affirmed.
Affirmed.
Mr. Chief Justice Brantly and Mr. Justice Holloway concur.